Fanuc alarm: 203 - PROGRAM MISS AT RIGID TAPPING
In the rigid tap, position for a rigid M code (M29) or an S command is incorrect. Modify the program.
None currently
In the rigid tap, position for a rigid M code (M29) or an S command is incorrect. Modify the program.
None currently
In the rigid tap, spindle distribution value is too large. (System error)
None currently
In the rigid tap, no F value is specified. Correct the program.
None currently
In the rigid tap, an S value is out of the range or is not specified. Modify the program.
None currently
Undefined macro word was used. Modify the custom macro.
None currently
The program specified a movement along the Cs-axis when the signal CON(DGN=G027#7) was off. Correct the program, or consult the PMC ladder diagram to find the reason the signal is not turned on.
None currently
The serial spindle control mode was not switched. Check the PMC ladder
program.
None currently
A contour control mode, spindle positioning (Cs-axis control) mode, or rigid tapping mode was specified during the serial spindle synchronous control mode. Correct the program so that the serial spindle synchronous control mode is released in advance.
None currently
In the constant surface speed control, the axis specification is wrong. (See parameter No. 3770.) The specified axis command (P) contains an illegal value. Correct the program.
None currently
Parameter error regarding G81 1) The C axis has not been set to be a rotary axis. 2) A hob axis and position coder gear ratio setting error Modify the parameter.
None currently