Fanuc

Fanuc alarm: 381 - n AXIS : ABNORMAL PHASE (EXT LIN)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
381 - n AXIS : ABNORMAL PHASE (EXT LIN)

Alarm Description

A phase data error occurred in the separate linear scale.

Additional Suggestions & Alarm Clarification

EXT= External feedback coder used possibly a scale or separate encoder. If a scale-dirt or contamination may be present on sensor or glass. Cleaning can sometimes fix the problem.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 381 - n AXIS : ABNORMAL PHASE (EXT LIN)) error message below.

Fanuc alarm: 380 - n AXIS : BROKEN LED (EXT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
380 - n AXIS : BROKEN LED (EXT)

Alarm Description

The separate detector is erroneous.

Additional Suggestions & Alarm Clarification

EXT= External feedback coder used possibly a scale or separate encoder. If a scale-dirt or contamination may be present on sensor or glass. Cleaning can sometimes fix the problem.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 380 - n AXIS : BROKEN LED (EXT)) error message below.

Fanuc alarm: 369 - n AXIS : DATA TRANS. ERROR (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
369 - n AXIS : DATA TRANS. ERROR (INT)

Alarm Description

A CRC or stop bit error occurred in the communication data being received from the built-in pulse coder.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 369 - n AXIS : DATA TRANS. ERROR (INT)) error message below.

Fanuc alarm: 368 - n AXIS : SERIAL DATA ERROR (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
368 - n AXIS : SERIAL DATA ERROR (INT)

Alarm Description

Communication data from the built-in pulse coder cannot be received.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 368 - n AXIS : SERIAL DATA ERROR (INT)) error message below.

Fanuc alarm: 367 - n AXIS : COUNT MISS (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
367 - n AXIS : COUNT MISS (INT)

Alarm Description

A count error occurred in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder or if scale may be dirty. You can try cleaning the scale

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 367 - n AXIS : COUNT MISS (INT)) error message below.

Fanuc alarm: 366 - n AXIS: PULSEMISS(INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
366 - n AXIS: PULSEMISS(INT)

Alarm Description

A pulse error occurred in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder or if scale may be dirty. You can try cleaning the scale

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 366 - n AXIS: PULSEMISS(INT)) error message below.

Fanuc alarm: 365 - n AXIS : BROKEN LED (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
365 - n AXIS : BROKEN LED (INT)

Alarm Description

An LED error occurred in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder or if scale may be dirty. You can try cleaning the scale

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 365 - n AXIS : BROKEN LED (INT)) error message below.

Fanuc alarm: 364 - n AXIS : SOFT PHASE ALARM (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
364 - n AXIS : SOFT PHASE ALARM (INT)

Alarm Description

The digital servo software detected invalid data in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder- replace it

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 364 - n AXIS : SOFT PHASE ALARM (INT)) error message below.

Fanuc alarm: 363 - n AXIS : ABNORMAL CLOCK (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
363 - n AXIS : ABNORMAL CLOCK (INT)

Alarm Description

A clock error occurred in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder- replace it

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 363 - n AXIS : ABNORMAL CLOCK (INT)) error message below.

Fanuc alarm: 362 - n AXIS : ABNORMAL REV.DATA (INT)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
362 - n AXIS : ABNORMAL REV.DATA (INT)

Alarm Description

A rotation speed count error occurred in the built-in pulse coder.

Additional Suggestions & Alarm Clarification

Most likely the pulse coder- replace it

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 362 - n AXIS : ABNORMAL REV.DATA (INT)) error message below.