Fanuc alarm: 443 - n AXIS : CNV. COOLING FAN FAILURE
1) PSM: The internal stirring fan failed. 2) PSMR: The internal stirring fan failed. 3) b series SVU: The internal stirring fan failed.
None currently
1) PSM: The internal stirring fan failed. 2) PSMR: The internal stirring fan failed. 3) b series SVU: The internal stirring fan failed.
None currently
1) PSM: The spare discharge circuit of the DC link is abnormal. 2) PSMR: The spare discharge circuit of the DC link is abnormal. 3) a series SVU: The dynamic brake circuit is abnormal.
None currently
The digital servo software detected an abnormality in the motor current detection circuit.
None currently
1) PSMR: The regenerative discharge amount is too large. 2) a series SVU: The regenerative discharge amount is too large. Alternatively, the regenerative discharge circuit is abnormal.
None currently
1) PSM: The DC link voltage is too high. 2) PSMR: The DC link voltage is too high. 3) a series SVU: The C link voltage is too high. 4) b series SVU: The link voltage is too high.
None currently
1) SVM: The motor current is too high. 2) a series SVU: The motor current is too high. 3) b series SVU: The motor current is too high.
None currently
PSM: Overcurrent flowed into the input circuit.
None currently
The digital servo software detected the soft thermal state (OVC).
None currently
SVM: The DC link voltage has dropped.
None currently
SVM: The control power supply voltage has dropped.
None currently