Fanuc alarm: 462 - n AXIS : SEND CNC DATA FAILED
Because of an FSSB communication error, a slave could not receive correct data.
None currently
Because of an FSSB communication error, a slave could not receive correct data.
None currently
The axes of the 2-axis amplifier were assigned to the fast type interface.
None currently
FSSB communication was disconnected suddenly. The possible causes are as follows: 1) The FSSB communication cable was disconnected or broken. 2) The power to the amplifier was turned off suddenly. 3) A low-voltage alarm was issued by the amplifier.
Check fiber optic cables for damage
Software disconnection alarm of the ? pulse coder.
Turn off the power to the CNC, then remove and insert the pulse coder
cable. If this alarm is issued again, replace the pulse coder.
None currently
1) SVM: IPM (intelligent power module) detected an alarm. 2) a series SVU: IPM (intelligent power module) detected an alarm.
Typically the drive needs to be replaced
The sign of feedback data from the built-in pulse coder differs from that of feedback data from the separate detector.
Check all cable connections to encoder and drives. Disconnecting cables may loose axes home position. Check for coolant in plugs and encoder area.
A broken wire in the separate detector was detected by hardware.
Check all cable connections to encoder and drives. Disconnecting cables may loose axes home position. Check for coolant in plugs and encoder area.
A broken wire in the built-in pulse coder was detected by hardware.
Check all cable connections to encoder and drives. Disconnecting cables may loose axes home position. Check for coolant in plugs and encoder area.
The digital servo software detected a broken wire in the pulse coder.
Check all cable connections to encoder and drives. Disconnecting cables may loose axes home position. Check for coolant in plugs and encoder area.
SVM: The internal stirring fan failed.
None currently
Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer