Fanuc

Fanuc alarm: 506 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
506 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side hardware OT.

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 506 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 505 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
505 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side stored stroke check III. (Parameter No.1325 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 505 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 504 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
504 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side stored stroke check III. (Parameter No.1324 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 504 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 503 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
503 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side stored stroke check II. (Parameter No.1323)

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 503 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 502 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
502 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side stored stroke check II. (Parameter No.1322 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 502 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 501 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
501 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side stored stroke check I. (Parameter No.1321 or 1327 NOTE)

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 501 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 500 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
500 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side stored stroke check I. (Parameter No.1320 or 1326 NOTE)

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 500 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 5n5 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
, 0/00/0-mate,
5n5 - OVER TRAVEL : -n

Alarm Description

A hardware overtravel occured in the positive direction of the n-axis.
(M series)

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5n5 - OVER TRAVEL : -n) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer