Fanuc

Fanuc alarm: 754 - SPINDLE-1 ABNORMAL TORQUE ALM

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
754 - SPINDLE-1 ABNORMAL TORQUE ALM

Alarm Description

Abnormal first spindle motor load has been detected.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 754 - SPINDLE-1 ABNORMAL TORQUE ALM) error message below.

Fanuc alarm: 752 - FIRST SPINDLE MODE CHANGE FAULT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
752 - FIRST SPINDLE MODE CHANGE FAULT

Alarm Description

This alarm is generated if the system does not properly terminate a mode change. The modes include the Cs contouring, spindle positioning, rigid tapping, and spindle control modes. The alarm is activated if the spindle control unit does not respond correctly to the mode change command issued by the NC.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 752 - FIRST SPINDLE MODE CHANGE FAULT) error message below.

Fanuc alarm: 751 - FIRST SPINDLE ALARM DETECTION(AL-XX)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
751 - FIRST SPINDLE ALARM DETECTION(AL-XX)

Alarm Description

This alarm indicates in the NC that an alarm is generated in the spindle
unit of the system with the serial spindle. The alarm is displayed in form
AL-XX (XX is a number). Refer to 2.3 or 2.4 Alarms displayed on
spindle servo unit .The alarm number XX is the number indicated on
the spindle amplifier. The CNC holds this number and displays on the
screen.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 751 - FIRST SPINDLE ALARM DETECTION(AL-XX)) error message below.

Fanuc alarm: 750 - SPINDLE SERIAL LINK START FAULT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
750 - SPINDLE SERIAL LINK START FAULT

Alarm Description

This alarm is generated when the spindle control unit is not ready for starting correctly when the power is turned on in the system with the serial spindle. The four reasons can be considered as follows: 1) An improperly connected optic cable, or the spindle control unit

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 750 - SPINDLE SERIAL LINK START FAULT) error message below.

Fanuc alarm: 749 - S-SPINDLE LSI ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
749 - S-SPINDLE LSI ERROR

Alarm Description

It is serial communication error while system is executing after power supply on. Following reasons can be considered. 1) Optical cable connection is fault or cable is not connected or cable is cut. 2) MAIN CPU board or option 2 board is fault. 3) Spindle amp. printed board is fault. If this alarm occurs when CNC power supply is turned on or when this alarm can not be cleared even if CNC is reset, turn off the power supply also turn off the power supply in spindle side.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 749 - S-SPINDLE LSI ERROR) error message below.

Fanuc alarm: 742 - RIGID TAP ALARM: LSI OVERFLOW

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
742 - RIGID TAP ALARM: LSI OVERFLOW

Alarm Description

An LSI overflow has occurred for the spindle during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 742 - RIGID TAP ALARM: LSI OVERFLOW) error message below.

Fanuc alarm: 741 - RIGID TAP ALARM: EXCESS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
741 - RIGID TAP ALARM: EXCESS ERROR

Alarm Description

The positional deviation of the moving spindle has exceeded the set value during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 741 - RIGID TAP ALARM: EXCESS ERROR) error message below.

Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
740 - RIGID TAP ALARM: EXCESS ERROR

Alarm Description

The positional deviation of the stopped spindle has exceeded the set value during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR) error message below.

Fanuc alarm: 704 - OVERHEAT: SPINDLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
704 - OVERHEAT: SPINDLE

Alarm Description

Spindle overheat in the spindle fluctuation detection (1) If the cutting load is heavy, relieve the cutting condition. (2) Check whether the cutting tool is share. (3) Another possible cause is a faulty spindle amp.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 704 - OVERHEAT: SPINDLE) error message below.

Fanuc alarm: 701 - OVERHEAT: FAN MOTOR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
701 - OVERHEAT: FAN MOTOR

Alarm Description

The fan motor on the top of the cabinet for the control unit is overheated. Check the operation of the fan motor and replace the motor if necessary.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 701 - OVERHEAT: FAN MOTOR) error message below.