Fanuc

Fanuc alarm: SR841 - CD OFF (3)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR841 - CD OFF (3)
Alarm Description

Signal quality detection signal of reader/puncher interface 3 turned off.

Additional Suggestions & Alarm Clarification

Check that RS232 cable is connected properly. Try another RS232 cable.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR841 - CD OFF (3) message please post comments below.

Fanuc alarm: SR840 - DR OFF (3)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR840 - DR OFF (3)
Alarm Description

Data set ready signal of reader/puncher interface 3 turned off.

Additional Suggestions & Alarm Clarification

Check that RS232 cable is connected properly. Try another RS232 cable.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR840 - DR OFF (3) message please post comments below.

Fanuc alarm: SR834 - BUFFER OVERFLOW (2)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR834 - BUFFER OVERFLOW (2)
Alarm Description

Data exceeding 10 characters were received after sending the stop code (DC3) when the NC receives data by reader/puncher interface 2.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR834 - BUFFER OVERFLOW (2) message please post comments below.

Fanuc alarm: SR833 - FRAMING ERROR (2)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR833 - FRAMING ERROR (2)
Alarm Description

Stop bit of a character received by reader/puncher interface 2 was not detected.

Additional Suggestions & Alarm Clarification

Check stop bit setting in RS232 software

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR833 - FRAMING ERROR (2) message please post comments below.

Fanuc alarm: SR832 - OVERRUN ERROR (2)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR832 - OVERRUN ERROR (2)
Alarm Description

The next character was received before reading a character received by reader/puncher interface 2

Additional Suggestions & Alarm Clarification

Check your RS232 Settings

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR832 - OVERRUN ERROR (2) message please post comments below.

Fanuc alarm: SR831 - CD OFF (2)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR831 - CD OFF (2)
Alarm Description

Signal quality detection signal of reader/puncher interface 2 turned off.

Additional Suggestions & Alarm Clarification

Check that RS232 cable is connected properly. Try another RS232 cable.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR831 - CD OFF (2) message please post comments below.

Fanuc alarm: SR830 - DR OFF (2)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR830 - DR OFF (2)
Alarm Description

Data set ready signal of reader/puncher interface 2 turned off.

Additional Suggestions & Alarm Clarification

Check that RS232 cable is connected properly. Try another RS232 cable.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR830 - DR OFF (2) message please post comments below.

Fanuc alarm: SR824 - BUFFER OVERFLOW (1) (RS232C-1)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR824 - BUFFER OVERFLOW (1) (RS232C-1)
Alarm Description

Data exceeding 10 characters were received after sending the stop code (DC3) when the NC receives data by reader/puncher interface 1.

Additional Suggestions & Alarm Clarification

Try turning baudrate for RS232 down and see if problem goes away.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR824 - BUFFER OVERFLOW (1) (RS232C-1) message please post comments below.

Fanuc alarm: SR823 - FRAMING ERROR (1)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR823 - FRAMING ERROR (1)
Alarm Description

Stop bit of a character received by reader/puncher interface 1 was not detected.

Additional Suggestions & Alarm Clarification

Check stop bit setting in RS232 software

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR823 - FRAMING ERROR (1) message please post comments below.

Fanuc alarm: SR822 - OVERRUN ERROR (1)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SR822 - OVERRUN ERROR (1)
Alarm Description

The next character was received before reading a character received by reader/puncher interface 1.

Additional Suggestions & Alarm Clarification

Check your RS232 Settings

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SR822 - OVERRUN ERROR (1) message please post comments below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer