Fanuc alarm: 1000 - EXTERNAL ALARM
This alarm was detected by the PMC ladder program. Refer to the
relevant manual from the machine builder for details.
None currently
- Read more about Fanuc alarm: 1000 - EXTERNAL ALARM
- Log in to post comments
This alarm was detected by the PMC ladder program. Refer to the
relevant manual from the machine builder for details.
None currently
This is a ROM parity error. Replace the ROM board in which the error
occurred.
None currently
This is a sub-CPU error. Replace the sub-CPU PC board. The abnormal 24VDC input power may be defective.
None currently
A fuse has blown. Replace the fuse (+24E; F14).
None currently
Communication is impossible with the second serial spindle. Ensure
that the second serial spindle is connected securely.
None currently
Communications error occured in the serial spindle.The optical fiber may be disconnected. The hardware configuration is incorrect for the serial spindle, or a communication alarm occurred. Check the hardware configuration of
the spindle. Also ensure that the hardware for the serial spindle is
connected securely.
None currently
The memory PC board is not connected securely. Ensure that the
PC board is connected securely.
None currently
PC board installation is incorrect. Check the specification of the PC
board.
None currently
CPU error (abnormal interrupt). The motherboard or CPU card may be faulty.
None currently
The digital servo module is not installed.
Check that the servo control module or servo interface module on the
main CPU or option 2 board is mounted securely.
None currently
Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer