I80
Yasnac I80 CNC alarms database listing and reference.
Yasnac-I80 CNC alarm: #9025
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL-6) (2) Error in specified parameter.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9025) error message below.
Yasnac-I80 CNC alarm: #9024
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL-5) (2) Sending or receiving start processing not conducted.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9024) error message below.
Yasnac-I80 CNC alarm: #9022
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL - 3) (2) Correct combination of dual core is not being used.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9022) error message below.
Yasnac-I80 CNC alarm: #9023
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL-4) (2) Transmission was not conducted during the specified time.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9023) error message below.
Yasnac-I80 CNC alarm: #9021
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL - (2) (2) Specified line is still not open.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9021) error message below.
Yasnac-I80 CNC alarm: #9020
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL-(1) (2) Specified line was already open.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9020) error message below.
Yasnac-I80 CNC alarm: #9020
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (APL-(1) (2) Specified line was already open.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9020) error message below.
Yasnac-I80 CNC alarm: #9019
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (FRAMING) (2) Error in RS-232C interface framing. (Improper stop-bit setting or transmission error)
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9019) error message below.
Yasnac-I80 CNC alarm: #9018
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (CH SELECT) (2) Error in selection of RS-232C interface circuit.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9018) error message below.
Yasnac-I80 CNC alarm: #9017
Control Manufacturer:
Yaskawa
Control Model:
I80 Yaskawa/Yasnac CNC Machine Alarm Description:
(1) RS-232C ERROR (OVER RUN) (2) Over 10 characters read after RS-232C interface stop code OUT.
Help Others:
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #9017) error message below.