90 - REFERENCE RETURN INCOMPLETE

Fanuc's Alarm Description: The reference position return cannot be performed normally because the reference position return start point is too close to the reference position or the speed is too slow. Separate the start point far enough from the reference position, or specify a sufficiently fast speed for reference position return. Check the program contents.