Fanuc alarm: 90 - REFERENCE RETURN INCOMPLETE
90 - REFERENCE RETURN INCOMPLETE
Fanuc's Alarm Description: The reference position return cannot be performed normally because the reference position return start point is too close to the reference position or the speed is too slow. Separate the start point far enough from the reference position, or specify a sufficiently fast speed for reference position return. Check the program contents.
Additional Suggestions & Alarm Clarification:
None currently
Help Others:
Post troubleshooting recommendations for (Fanuc alarm: 90 - REFERENCE RETURN INCOMPLETE) error message below.
Fanuc CNC Control Models Applicable:
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
Manufacturing | Industrial | CNC machinist | Maintenance | Repair