115 - ILLEGAL VARIABLE NUMBER

Fanuc's Alarm Description: A value not defined as a variable number is designated in the custom macro or in high-speed cycle machining. The header contents are improper. This alarm is given in the following cases: High speed cycle machining 1. The header corresponding to the specified machining cycle number called is not found. 2. The cycle connection data value is out of the allowable range (0 -999). 3. The number of data in the header is out of the allowable range (0 -32767). 4. The start data variable number of executable format data is out of the allowable range (#20000 -#85535). 5. The last storing data variable number of executable format data is out of the allowable range (#85535). 6. The storing start data variable number of executable format data is overlapped with the variable number used in the header. Modify the program.